Skip to content

Accuracy

How we validate the analysis

Methodology

Model scores were compared with clinicians' average scores on the same scale.

What the figure means

It is agreement with clinicians' assessment — not a share of correct diagnoses and not "diagnostic accuracy". Scanderm assesses the aesthetic condition of skin.

Limitations

  • The result was obtained on a sample of 88 photographs and does not automatically transfer to any shooting conditions.
  • Analysis quality depends on lighting, angle and photo quality.
  • The analysis does not replace a doctor's consultation and is not a diagnosis.

Validation results by module

Facial skin

94,8%

agreement with the average assessment of clinicians

88 new photos, 0–10 scale, panel of 5 doctors (Oct 2025). 94.5% of scores within 3 points, 86% within 2; mean error 1.1 points vs 0.57 spread between doctors; panel ICC 0.914.

Teeth (signs of caries)

91,9% / 77,0%

per-photo sensitivity / specificity

Internal validation: 250 photos, 2,194 teeth, 433 doctor-marked lesions. Per photo: NPV 90.7%. Per tooth: sensitivity 70.8%, specificity 95.6%.

Preliminary screening, not a medical device.

Results by feature group

Calculation and study protocol available on request.

Request a demo